1. The boiler plant consists of the following equipment:
- steam boiler E 25-39-440 with a furnace of high-temperature fluidized bed (WTCS);
- Economizer
2.1. The basic technical characteristics and requirements for the steam boiler:
Name of parameters |
Unit |
Value |
Fuel - middlings (by-product coal) |
- |
- |
boiler steaming capacity |
T/h |
25 |
Steam pressure at the steam superheater outlet (excessive pressure) |
MPa |
3,9 |
Superheated steam temperature |
°С |
440 |
Feedwater temperature |
°С |
145 |
Slag dust removal – dry |
|
|
2.2 Technical characteristics of fuel:
Name of parameters |
Unit |
Value |
operating humidity |
% |
10-15 |
Ash content in as-received basis |
% |
35-45 |
Devolatilization in as-received basis |
% |
20-25 |
low heat value |
Kcal / kg |
3000-4500 |
high heat value |
Kcal / kg |
7800-8300 |
3. General requirements for boiler installation
3.1 Ensure a stable burning of fuel in the boiler plant furnace.
3.1.1. Ensure boiler plant operation on the middlings with the following steam parameters:
- absolute pressure 3,9 MPa;
- temperature 440 0С;
- Steam capacity 25 t/h
25 T/H Coal Fired Steam Boiler
3.2. Provide steam capacity of the boiler in the control range from 30 to 110% of the rated load.
3.3. The boiler plant must comply with the requirements of this technical specification.
3.4. All delivered equipment must have certificates of conformity, the necessary marking, passports, instructions for installation and operation, the corresponding results of control.
3.5. The quality of the steam according to its content must comply with the requirements of normative technical documentation for power plants of medium parameters (GOST 20995-75).
3.6. The boiler installation should be provided with thermal insulation with a protective layer so that the surface temperature of the heated and heating elements of the equipment does not exceed 450 ° C.
For all inquiries, please fill in the form below (* are required) to send us a brief message, and we will get back to you as soon as possible.