ZBG group factory direct sales Q=20t/h circulating fluidized bed steam boiler

2023-07-27 08:52:30

According to the different production capacities of equipment manufacturers, the bidding equipment is divided into four packages: A, B, C, and D. They are as follows:

1. Specifications of circulating fluidized bed boiler and auxiliary equipment

Package A: boiler and supporting equipment

serial number Equipment name unit quantity price Manufacturing department or remarks
1 Circulating fluidized bed steam boiler tower 2    
2 Primary Fan tower 2    
3 Secondary fan tower 2    
4 Coal feeder tower 4    
5 Cold slag machine tower 2    
6 Auxiliary materials, instruments, pipelines and valves set 2    
7 Sample cooler set 4    
8 Spare parts and random information set 2    

Package B: water treatment and pumping equipment

serial number Equipment name unit quantity price Manufacturing department or remarks
1 Combined automatic sodium ion exchanger Group 1   two tank exchanger
2 soft water tank Only 2   SMC assembly
3 Atmospheric thermal deaerator tower 2      
4 Continuous blowdown expander tower 1    
5 Periodic sewage expansion container tower 1    
6 Electric feed water pump tower 3      
7 Deaeration pump tower 3      

Package C: flue gas treatment equipment

serial number Equipment name unit quantity price Manufacturing department or remarks
1 Pulse bag filter set 2    
2 Calcium injection desulfurization device in dilute phase furnace set 2    

Package D: heat exchange device

serial number Equipment name unit quantity price Manufacturing department or remarks
1 heat exchange unit Group 2    
2 water tank tower 1    
3 Water collection tank tower 1    
4 Sub-cylinder tower 1    

2. Technical parameters of boiler equipment

1) Circulating fluidized bed steam boiler

Model: ZG20-1.6-ALL external circulating fluidized bed boiler

Rated steam evaporation: Q=20t/h

Rated outlet steam pressure: P=1.6MPa

Rated outlet steam temperature: 214°C

Rated feed water temperature: 104°C

Fuel: bituminous coal (the fuel characteristics will be provided by Party A after winning the bid, and the bid-winning manufacturer will design the boiler according to the fuel characteristics)

Design thermal efficiency: >87%

Furnace structure: membrane water wall

Hot air temperature (primary/secondary): 107/20°C

Exhaust gas temperature: <140°C

Matching economizer and air preheater

2) Primary fan

Air volume: Q=26003m3/h (standard condition)

Wind pressure: H=14177Pa (standard condition)

Power: N=160kW

Correct the wind pressure and air volume in the plateau area according to its own equipment,

The project location is 1140m above sea level,

The operating temperature refers to the local meteorological parameters in the tender.

3) Secondary fan

Air volume: Q=8294m3/h (standard condition)

Wind pressure: H=4453Pa (standard condition)

Power: N=37kW

Correct the wind pressure and air volume in the plateau area according to its own equipment,

The project location is 1140m above sea level,

The operating temperature refers to the local meteorological parameters in the tender.

4) Induced fan

Air volume: Q=72380m3/h (standard condition)

Wind pressure: H=4571Pa (standard condition)

Power: N=160kW

Correct the wind pressure and air volume in the plateau area according to its own equipment,

The project location is 1140m above sea level,

The operating temperature refers to the local meteorological parameters in the tender.

After the boiler desulfurization and dust removal equipment is determined, the wind pressure needs to be calculated.

5) Spiral coal feeder

GM-200 (one boiler is equipped with two sets, matching 20t/h boiler)

6) Drum type slag cooling machine

Conveying capacity: 2t/h (if the boiler has two slag outlets, configure 2 sets of 1t/h)

Reducer power: 3.0Kw

Material inlet temperature: <1000°C

Material outlet temperature: <80°C

Cooling water inlet temperature: 20~30℃

Cooling water outlet temperature: <80°C

Pressure loss: 0.08MPa

7) Auxiliary materials and accessories

The boiler factory is equipped with auxiliary materials and accessories such as cyclone separator, coal spreading fan, furnace wall cooling fan, feeding fan, wind cap, pipeline, valve and instrument that meet the operation requirements of the boiler body. (Centralized control is another consideration).

8) Sample cooler

XN0010.0

9) Spare parts and accompanying documents

Spare parts required for the boiler and its auxiliary equipment within a two-year period of operation.

Products Recommended
Vulcanization Tank
Vulcanization Tank Customized
Pressure: 0.45-1.3MPa (4.5 - 13bar)
DHL Corner Tube Biomass Fired Bo
DHL Corner Tube Biomass Fired Bo 10-160 t/7-112 MW
Pressure: ≤5.29MPa
Biomass Power Plant Boiler
Biomass Power Plant Boiler 10 - 75 t/ 7-52.5 MW
Pressure: ≤5.29MPa
Biomass Fired CFB Boiler
Biomass Fired CFB Boiler 20-280 t/ 14-196 MW
Pressure: ≤5.29MPa
Success Stories
100 Tons CFB Boiler in Zhengjian
100 Tons CFB Boiler in Zhengjian Application: Thermal Power Plant
Capacity: 100 Tons
1 Ton Gas Steam Boiler in Chile
1 Ton Gas Steam Boiler in Chile Application: Rubber Vulcanization
Capacity: 1 Ton/hr
6 ton biomass steam boiler in Ir
6 ton biomass steam boiler in Ir Application: paper industry
Capacity: 6 ton
15 ton diesel steam boiler in Pu
15 ton diesel steam boiler in Pu Application: tire factory
Capacity: 15 ton
Checking Order Quality Test Before Delivery Check Items When Packing Packaging And Transport
Get An Instant Quotation

For all inquiries, please fill in the form below (* are required) to send us a brief message, and we will get back to you as soon as possible.

Product:
* Email:
Tel:
Name:
Boiler fuel:
  • Gas
  • Oil
  • Biomass
  • Coal
  • Waste Heat
  • Other
Application:
  • Textile Industry
  • Central Heating
  • Food Plant
  • Power Plant
  • Chemical Industry
  • Waste Heat Recovery
  • AAC Block Plant
  • Hotel & Resort
  • CHP
  • Other