Media Center
HomeMedia CenterZBG Info

5 Ton Gas Steam Boiler Technical Parameter Table

2022-10-08 08:44:51

 5 Ton Gas Steam Boiler Technical Parameter Table

General Site Operating Conditions
Parameter   Unit Value
Ambient temperature ⁰C Refer to site conditions spec
Maximum operating temp ⁰C Refer to site conditions spec
Mean temperatures (Min/Max) ⁰C Refer to site conditions spec
Process / Design Data
      Project Design Data
Service Area(s) Text Utilities and Services area
Service Description Text Produce medium pressure steam
Location  Text Outdoors
Arrangement Text Steam boiler package complete with all required ancillaries
Rated Capacity t/h 5.0
Feed Water       
Water Specification Text Demineralised
Demin water flow rate m3/h  
Demin water supply pressure kPa(g)  
Demin water temperature ⁰C  
Demin water quality    
Chlorides ppm < 2
Silicate ppm < 2
Iron ppm < 2
Calcium ppm < 10
Treatment chemicals requirement (Consumption & type) Text  
Steam Production      
Design steam rate required t/h 6
Steam Production      
Pressure kPa(g) 700
Temperature ⁰C 165
Steam Quality Text Saturated
Fuel      
Type Text Natural Gas
Quality Text Refer to site conditions
Natural Gas Consumption rate Nm3/h  
Natural Gas supply pressure kPa(g)  
     
Electrical Design Data
  Units Project Design Data
Electrical supply voltage V 415±10% Vac
Electrical supply phase no. 3
Electrical supply frequency Hz 50±2%
Motor enclosure rating IP IP 56 (min)
Start/Stop Input   Purchaser PLC
Electrical control voltage V 24 Vdc
Mechanical Package Type   2
Required Motor Manufacturer   WEG (W22)
Motor starter type    
Electrical cabinet enclosure rating IP IP56
     
Instrumentation / Control Design Data
Instrumentation / Control  Units Project Design Data
Valves Text  
  Text  
Other instruments(vendor to advise) Text  
  Text  
  Text  
     
Mechanical Design Data
  Units Project Design Data
Supplier Text  
Manufacturer Text  
Model Text  
Plant arrangement Text  
Boiler Type Text Gas Fired
Number of Boilers Text  
Feed pump requirements Text  
     
Services Requirement Data
  Units Project Design Data
Plant / Instrument Air      
Air supply pressure kPa(g) 700
Quantity of air required Nm3/h  
Power      
Voltage / Frequency / Phase V/Hz/Ph 415 / 50 / 3
Other Services      
     
     
     
Equipment Geometry
  Project Design Data
Geometry    
General Arrangement / Detail Drawing Text  
Overall Package Dimensions mm x mm x mm  
Assembly    
Number of modules #  
       
Materials of Construction
  Project Design Data
       
Boiler   Thk/Mat'l  
Burner   Mat'l  
Valve   Mat'l  
Reinforcement Plates   Mat'l  
Structural Steelwork and platforms   Mat'l  
Pipework / Ducting   Mat'l  
       
Surface Preparation and Painting
  Project Design Data
       
Plant Area Classification Text Refer to Surface Preparation Specification
Structural Steelwork and Plaforms Text Refer to Surface Preparation Specification
Internal Text Refer to Surface Preparation Specification
External Text Refer to Surface Preparation Specification
External lagging and thickness Text / mm  
       
Transport Data
  Project Design Data
Weight and Loads  
Total Mass (operating)   kg  
Maximum single lift for installation   kg  
Maximum single lift for maintenance   kg  
Total shipping weight   kg  
Structural and platforms   kg  
Ducts, Pipeworks and manifolds   kg  
       
Comments
1. Vendor to provide sizing and pricing based on info in this datasheet, inform client of any specifications which do not conform to this data sheet and clearly define scope of supply and battery limits.
2. Vendor shall fit equipment with adequate certified lifting lugs for transportation and installation and shall provide installation details as well as details regarding points of attachment.
3. Vendor to provide full separate details of all subcomponents (i.e. full pump details, full motor details, etc).          
4. General Arrangement Drawings to include all major dimensions and maintenance envelopes
5. 1 Nm3 is the quantity of gas occupying 1 m3 at 0°C and 101.3kPa (abs), including moisture.
6. Vendor to specify instrument/control type in the "Title" column and instrument Make/Model in the "Vendor Data" column
7. Vendor to advise any additional code requirements.
8. All equipment on ancillaries to be sized based on 120% of normal duty specified above
Products Recommended
Vulcanization Tank
Vulcanization Tank Customized
Pressure: 0.45-1.3MPa (4.5 - 13bar)
DHL Corner Tube Biomass Fired Bo
DHL Corner Tube Biomass Fired Bo 10-160 t/7-112 MW
Pressure: ≤5.29MPa
Biomass Power Plant Boiler
Biomass Power Plant Boiler 10 - 75 t/ 7-52.5 MW
Pressure: ≤5.29MPa
Biomass Fired CFB Boiler
Biomass Fired CFB Boiler 20-280 t/ 14-196 MW
Pressure: ≤5.29MPa
Success Stories
100 Tons CFB Boiler in Zhengjian
100 Tons CFB Boiler in Zhengjian Application: Thermal Power Plant
Capacity: 100 Tons
1 Ton Gas Steam Boiler in Chile
1 Ton Gas Steam Boiler in Chile Application: Rubber Vulcanization
Capacity: 1 Ton/hr
6 ton biomass steam boiler in Ir
6 ton biomass steam boiler in Ir Application: paper industry
Capacity: 6 ton
15 ton diesel steam boiler in Pu
15 ton diesel steam boiler in Pu Application: tire factory
Capacity: 15 ton
Checking Order Quality Test Before Delivery Check Items When Packing Packaging And Transport
Get An Instant Quotation

For all inquiries, please fill in the form below (* are required) to send us a brief message, and we will get back to you as soon as possible.

Product:
* Email:
Tel:
Name:
Boiler fuel:
  • Gas
  • Oil
  • Biomass
  • Coal
  • Waste Heat
  • Other
Application:
  • Textile Industry
  • Central Heating
  • Food Plant
  • Power Plant
  • Chemical Industry
  • Waste Heat Recovery
  • AAC Block Plant
  • Hotel & Resort
  • CHP
  • Other