Coal mine production needs steam, wellhead heating and office dormitory area heating in winter need heating. The project user unit plans to purchase two 4-ton gas fired steam boilers to meet production and heating needs. The following is an introduction to the technical parameters of gas boilers.
Gas steam boiler technical parameter table | |||
name | unit | value | Remark |
Boiler rated evaporation | t/h | 4 | |
work pressure | MPa | 1.25 | |
Rated steam temperature | ℃ | ≥190 | |
Feed water temperature | ℃ | ≥20 | |
Radiation heating area | m | ≥11 | |
convection heating area | m | ≥84 | |
Tail heated area | m | ≥21 | |
boiler efficiency | % | ≥91 | |
Hydrostatic test pressure | MPa | 1.65 | |
water volume | m | ≥5 | |
adaptive fuel | / | light oil, natural gas | |
fuel low calorific value | MJ/Nm | ≥35.438 | |
fuel consumption | Nm /h | ≤334 | |
burning method | / | micro positive pressure chamber combustion | |
exhaust temperature | ℃ | ≤135.75 | |
Excess Air Coefficient at Smoke Exhaust | / | ≥1.15 | |
Stable operating range | % | 80-100 |
1) Smoke emission concentration: 0mg/m³;
2) SO2 emission concentration: 0mg/m³;
3) Nitrogen and oxygen emission concentration: 50mg/m³;
4) Single noise: ≤85 decibels.
For all inquiries, please fill in the form below (* are required) to send us a brief message, and we will get back to you as soon as possible.