Sl.No | Item descriptions | AMEL's requirement. |
1 | Boiler Model No |
|
2 | Maximum continuous rating (MCR) | Please specify |
3 | Net continuous rating (NCR) | 50 MT/Hr. |
4 | Steam temperature⁰C | 380 |
5 | Steam pressure at MSSR | 32 Bar |
6 | Deaerator temperature⁰C inlet | 80 |
7 | Deaerator temperature⁰C outlet | 105 |
8 | Internal consumption of steam for Boiler/hour (Deaerator & others, if any). | |
9 | Fuel | Natural Gas - TITAS |
10 | Gas composition | Refer to the attachment. |
11 | GCV (BTU/ft3) | 1032 |
12 | Efficiency% on NCV | Please specify& furnish calculation sheet. |
13 | Boiler tube material | SA192 / SA210 preferred |
14 | Superheater tube material | SA213T22 preferred |
15 | Economizer tube material | SA192 / SA210 preferred |
16 | Boiler steam drum material | SA-516 Grade 70 is preferred |
17 | Boiler water drum material | SA516Grade 70 is preferred |
18 | Furnace tube Fin Width mm | Please specify |
Boiler heating surface area,FT2 | Please specify | |
19 | Economizer heating area,FT2 | Please specify |
20 | Superheater heating area,FT2 | Please specify |
21 | Fuel consumption (Nm3/hr/ton) | Please specify |
22 | PLC with DCS | Please include |
23 | Chimney design & material | Submit separate technical & commercial offer. |
24 | Feed water quality | Please specify |
25 | Steam purity | Please specify |
26 | Stack temperature⁰C | Please specify |
27 | Maximum gas pressure bar | Max 2 Bar |
28 | CO2% | 10-12% is preferred |
29 | Burner capacity,Mkcal/hr | Please specify |
30 | FD Fan capacity,Nm3/hr | Please specify |
31 | FD fan, KW | Please specify |
32 | VFD for FD fan operation | Please Include |
33 | Emission levels of flue gas | Please specify |
34 | Feed water pump, KW, V | 400 V / specify kw. |
35 | Instrument air, bar | 5.5-7 |
36 | Electricity KW per ton steam generated (NCR basis) | Please provide |
37 | Deaerator | Please Include |
38 | Chemical feed system | Please Include |
39 | Steam flow meter | Please Include |
40 | Steam pressure high & high-high & furnace pressure high switch | Please Include |
41 | Blowdown tank & conductivity control system | Please Include |
42 | Duct & external insulation | Please Include |
43 | Client list | Please provide |
44 | Spares for two years operation. | Please furnish a list & separate offer |
45 | Delivery time, months | Please provide |
46 | Warranty after commissioning, months | Please provide |
47 | Total Gas consumption for 50MT/Hour steam output in Nm3 (NCR basis) | Please furnish. |
48 | Heat balance sheet (NCR Basis) | Please provide |